Baxi boiler fault codes

Codes and operating messages for 800 Combi 2 (824, 830 and 836). Check your exact boiler model before using this guide.

74 results

  • H.02.07

    Temporary fault

    Heating system water pressure has stayed below the minimum operating level.

  • E.04.10

    Lockout

    The burner failed to light after four attempts. The boiler has stopped in lockout.

  • E.04.08

    Lockout

    The safety system stopped the boiler at its upper temperature limit.

  • A.00.34

    Warning

    The boiler is set up to use an outdoor temperature sensor but cannot detect it.

  • A.02.06

    Warning

    The controls are warning that the water pressure in the heating circuit is low.

  • A.02.18

    Warning

    The boiler has detected an error in its configuration or on-board diagnostics.

  • A.02.36

    Warning

    The boiler has lost contact with an active accessory or expansion module.

  • A.02.37

    Warning

    The boiler has lost contact with a passive accessory or module.

  • A.02.45

    Warning

    The boiler is reporting a connection problem with an accessory.

  • A.02.46

    Warning

    The controls detected a conflict in the priority of connected devices.

  • A.02.48

    Warning

    A connected unit is configured for the wrong function or has invalid settings.

  • A.02.49

    Warning

    The boiler could not start a connected communication module.

  • A.02.54

    Warning

    There is a power supply fault on the OpenTherm control connection.

  • A.02.55

    Warning

    The stored serial number is missing or invalid.

  • A.02.76

    Warning

    The settings memory cannot accept any more changes.

  • E.00.04

    Lockout

    The return temperature sensor has lost its connection or has a break in its circuit.

  • E.00.05

    Lockout

    A short circuit has been detected at the return temperature sensor.

  • E.00.06

    Lockout

    The boiler expects to find the return temperature sensor but cannot detect it.

  • E.00.07

    Lockout

    The controls detected an excessive difference in the return temperature readings.

  • E.00.16

    Lockout

    The boiler is getting no signal from the hot-water cylinder temperature sensor, where fitted.

  • E.00.17

    Lockout

    The hot-water cylinder sensor circuit has shorted, where fitted.

  • E.00.20

    Lockout

    The flue temperature sensor signal is missing or its reading is below range.

  • E.00.21

    Lockout

    The flue temperature sensor circuit has shorted or is reading above range.

  • E.01.04

    Lockout

    The boiler lost its flame five times within 24 hours while the burner was running.

  • E.01.12

    Lockout

    The return water sensor is reading hotter than the flow water sensor.

  • E.01.17

    Lockout

    A continuing loss of water circulation has put the boiler into lockout.

  • E.01.20

    Lockout

    The flue gases reached the permitted temperature limit.

  • E.02.13

    Lockout

    An external control has stopped the boiler and frost protection is inactive.

  • E.02.15

    Lockout

    The boiler timed out waiting for a response from an external control board.

  • E.02.17

    Lockout

    Communication between the boiler controls and the gas valve has failed persistently.

  • E.02.35

    Lockout

    The boiler detected that an essential safety device is disconnected.

  • E.02.47

    Lockout

    The controls could not connect to an external device.

  • E.04.00

    Lockout

    The controls rejected the level 5 safety settings.

  • E.04.01

    Lockout

    The flow temperature sensor circuit has shorted.

  • E.04.02

    Lockout

    The flow temperature sensor has lost its connection or has a break in its circuit.

  • E.04.03

    Lockout

    The flow reading is above its allowed temperature. A shorted sensor can also trigger this fault.

  • E.04.07

    Lockout

    The two flow temperature readings differ by more than the boiler allows.

  • E.04.09

    Lockout

    Two flue temperature sensors reported readings that differ by too much.

  • E.04.11

    Lockout

    The safety test that checks the gas valve did not pass.

  • E.04.12

    Lockout

    The boiler has recorded an ignition failure relating to an unexpected flame signal.

  • E.04.13

    Lockout

    The fan may be jammed or have exceeded its approved speed.

  • E.04.14

    Lockout

    The controls detected a persistent difference between the burner temperature and the configured gas control setting.

  • E.04.15

    Lockout

    The boiler detected a blockage in its flue outlet.

  • E.04.17

    Lockout

    The boiler has detected an electrical fault in the gas valve control circuit.

  • E.04.18

    Lockout

    The flow temperature is below the lower limit or the temperature sensor has lost its connection.

  • E.04.19

    Lockout

    The controls have lost communication with the mass-flow sensor.

  • E.04.20

    Lockout

    The mass-flow sensor reading is further from its expected value than the boiler allows.

  • E.04.21

    Lockout

    The two burner temperature readings disagree. The model guide marks this condition as unavailable.

  • E.04.23

    Lockout

    The controls detected an internal stoppage in the gas valve assembly.

  • E.04.24

    Lockout

    The controls could not automatically identify the gas type. The model guide marks this condition as unavailable.

  • E.04.54

    Lockout

    The boiler has detected an electrical fault in the gas valve control circuit.

  • H.00.42

    Temporary fault

    The pressure sensor may be faulty or its circuit may be open.

  • H.01.00

    Temporary fault

    Communication between the gas valve and the boiler controls briefly dropped out.

  • H.01.05

    Temporary fault

    The temperature gap between water leaving and returning to the boiler has reached its limit.

  • H.01.08

    Temporary fault

    The heating flow temperature rose too fast, so the boiler pauses for 10 minutes.

  • H.01.14

    Temporary fault

    The flow temperature has reached the limit in the model’s manual.

  • H.01.18

    Temporary fault

    The boiler briefly detected no circulation in the heating circuit.

  • H.01.21

    Temporary fault

    The flow heated up too fast while making hot water, so the boiler pauses for 10 minutes.

  • H.02.00

    Operating status

    The control system is currently resetting.

  • H.02.02

    Temporary fault

    The controller is waiting for its CN1 and CN2 configuration values.

  • H.02.03

    Temporary fault

    The controller rejected the CN1 and CN2 configuration values.

  • H.02.04

    Temporary fault

    The boiler cannot read the control board settings.

  • H.02.05

    Temporary fault

    The saved settings are incompatible with the boiler’s control board.

  • H.02.09

    Temporary fault

    Some boiler functions are stopped while frost protection stays active.

  • H.02.10

    Temporary fault

    The boiler has stopped completely and frost protection is inactive.

  • H.02.12

    Temporary fault

    The input contact from an external controller is open.

  • H.02.38

    Temporary fault

    The controls report missing water-hardness data. The model guide marks this condition as unavailable.

  • H.02.70

    Temporary fault

    An external heat-recovery device failed its test, where one is fitted.

  • H.03.00

    Temporary fault

    The boiler cannot read the identification data for its safety device.

  • H.03.01

    Temporary fault

    Communication failed in an internal circuit on the boiler’s control board.

  • H.03.02

    Temporary fault

    The boiler briefly lost its flame.

  • H.03.05

    Temporary fault

    The voltage supplied to the boiler is too low.

  • H.03.17

    Operating status

    The boiler is running its scheduled safety test.

  • H.03.54

    Temporary fault

    The flame went out and the boiler stopped when the supply voltage fell too low.

Source Baxi manufacturer documentation.