Baxi boiler fault codes
Codes and operating messages for 800 Combi 2 (824, 830 and 836). Check your exact boiler model before using this guide.
74 results
- H.02.07
Temporary fault
Heating system water pressure has stayed below the minimum operating level.
- E.04.10
Lockout
The burner failed to light after four attempts. The boiler has stopped in lockout.
- E.04.08
Lockout
The safety system stopped the boiler at its upper temperature limit.
- A.00.34
Warning
The boiler is set up to use an outdoor temperature sensor but cannot detect it.
- A.02.06
Warning
The controls are warning that the water pressure in the heating circuit is low.
- A.02.18
Warning
The boiler has detected an error in its configuration or on-board diagnostics.
- A.02.36
Warning
The boiler has lost contact with an active accessory or expansion module.
- A.02.37
Warning
The boiler has lost contact with a passive accessory or module.
- A.02.45
Warning
The boiler is reporting a connection problem with an accessory.
- A.02.46
Warning
The controls detected a conflict in the priority of connected devices.
- A.02.48
Warning
A connected unit is configured for the wrong function or has invalid settings.
- A.02.49
Warning
The boiler could not start a connected communication module.
- A.02.54
Warning
There is a power supply fault on the OpenTherm control connection.
- A.02.55
Warning
The stored serial number is missing or invalid.
- A.02.76
Warning
The settings memory cannot accept any more changes.
- E.00.04
Lockout
The return temperature sensor has lost its connection or has a break in its circuit.
- E.00.05
Lockout
A short circuit has been detected at the return temperature sensor.
- E.00.06
Lockout
The boiler expects to find the return temperature sensor but cannot detect it.
- E.00.07
Lockout
The controls detected an excessive difference in the return temperature readings.
- E.00.16
Lockout
The boiler is getting no signal from the hot-water cylinder temperature sensor, where fitted.
- E.00.17
Lockout
The hot-water cylinder sensor circuit has shorted, where fitted.
- E.00.20
Lockout
The flue temperature sensor signal is missing or its reading is below range.
- E.00.21
Lockout
The flue temperature sensor circuit has shorted or is reading above range.
- E.01.04
Lockout
The boiler lost its flame five times within 24 hours while the burner was running.
- E.01.12
Lockout
The return water sensor is reading hotter than the flow water sensor.
- E.01.17
Lockout
A continuing loss of water circulation has put the boiler into lockout.
- E.01.20
Lockout
The flue gases reached the permitted temperature limit.
- E.02.13
Lockout
An external control has stopped the boiler and frost protection is inactive.
- E.02.15
Lockout
The boiler timed out waiting for a response from an external control board.
- E.02.17
Lockout
Communication between the boiler controls and the gas valve has failed persistently.
- E.02.35
Lockout
The boiler detected that an essential safety device is disconnected.
- E.02.47
Lockout
The controls could not connect to an external device.
- E.04.00
Lockout
The controls rejected the level 5 safety settings.
- E.04.01
Lockout
The flow temperature sensor circuit has shorted.
- E.04.02
Lockout
The flow temperature sensor has lost its connection or has a break in its circuit.
- E.04.03
Lockout
The flow reading is above its allowed temperature. A shorted sensor can also trigger this fault.
- E.04.07
Lockout
The two flow temperature readings differ by more than the boiler allows.
- E.04.09
Lockout
Two flue temperature sensors reported readings that differ by too much.
- E.04.11
Lockout
The safety test that checks the gas valve did not pass.
- E.04.12
Lockout
The boiler has recorded an ignition failure relating to an unexpected flame signal.
- E.04.13
Lockout
The fan may be jammed or have exceeded its approved speed.
- E.04.14
Lockout
The controls detected a persistent difference between the burner temperature and the configured gas control setting.
- E.04.15
Lockout
The boiler detected a blockage in its flue outlet.
- E.04.17
Lockout
The boiler has detected an electrical fault in the gas valve control circuit.
- E.04.18
Lockout
The flow temperature is below the lower limit or the temperature sensor has lost its connection.
- E.04.19
Lockout
The controls have lost communication with the mass-flow sensor.
- E.04.20
Lockout
The mass-flow sensor reading is further from its expected value than the boiler allows.
- E.04.21
Lockout
The two burner temperature readings disagree. The model guide marks this condition as unavailable.
- E.04.23
Lockout
The controls detected an internal stoppage in the gas valve assembly.
- E.04.24
Lockout
The controls could not automatically identify the gas type. The model guide marks this condition as unavailable.
- E.04.54
Lockout
The boiler has detected an electrical fault in the gas valve control circuit.
- H.00.42
Temporary fault
The pressure sensor may be faulty or its circuit may be open.
- H.01.00
Temporary fault
Communication between the gas valve and the boiler controls briefly dropped out.
- H.01.05
Temporary fault
The temperature gap between water leaving and returning to the boiler has reached its limit.
- H.01.08
Temporary fault
The heating flow temperature rose too fast, so the boiler pauses for 10 minutes.
- H.01.14
Temporary fault
The flow temperature has reached the limit in the model’s manual.
- H.01.18
Temporary fault
The boiler briefly detected no circulation in the heating circuit.
- H.01.21
Temporary fault
The flow heated up too fast while making hot water, so the boiler pauses for 10 minutes.
- H.02.00
Operating status
The control system is currently resetting.
- H.02.02
Temporary fault
The controller is waiting for its CN1 and CN2 configuration values.
- H.02.03
Temporary fault
The controller rejected the CN1 and CN2 configuration values.
- H.02.04
Temporary fault
The boiler cannot read the control board settings.
- H.02.05
Temporary fault
The saved settings are incompatible with the boiler’s control board.
- H.02.09
Temporary fault
Some boiler functions are stopped while frost protection stays active.
- H.02.10
Temporary fault
The boiler has stopped completely and frost protection is inactive.
- H.02.12
Temporary fault
The input contact from an external controller is open.
- H.02.38
Temporary fault
The controls report missing water-hardness data. The model guide marks this condition as unavailable.
- H.02.70
Temporary fault
An external heat-recovery device failed its test, where one is fitted.
- H.03.00
Temporary fault
The boiler cannot read the identification data for its safety device.
- H.03.01
Temporary fault
Communication failed in an internal circuit on the boiler’s control board.
- H.03.02
Temporary fault
The boiler briefly lost its flame.
- H.03.05
Temporary fault
The voltage supplied to the boiler is too low.
- H.03.17
Operating status
The boiler is running its scheduled safety test.
- H.03.54
Temporary fault
The flame went out and the boiler stopped when the supply voltage fell too low.
Source Baxi manufacturer documentation.