Ideal Heating boiler fault codes

Codes and operating messages for Logic Combi² C24, C30 and C35. Check your exact boiler model before using this guide.

27 results

  • F01

    Fault

    The heating circuit pressure is below the level the boiler needs to operate correctly.

  • L02

    Lockout

    The burner could not light and the boiler has locked out. A gas supply fault or blocked condensate drain can be involved.

  • L01

    Lockout

    The boiler has locked out after a high flow temperature reading. A lack of water circulation can cause this.

  • dU

    Service mode

    The diverter valve is held between the heating and hot-water positions for servicing.

  • F0C

    Fault

    There is a fault with the hot-water temperature sensor.

  • F0t

    Fault

    There is a problem with the room thermostat or its connection to the boiler.

  • F0U

    Fault

    The outgoing water is over 50°C hotter than the returning water. Poor circulation can cause this.

  • F02

    Fault

    The boiler lost its flame during operation.

  • F03

    Fault

    The boiler detected a fault in the fan or its electrical circuit.

  • F04

    Sensor fault

    The sensor measuring water temperature as it leaves the boiler is giving a faulty reading.

  • F05

    Sensor fault

    The sensor measuring water temperature as it returns to the boiler is giving a faulty reading.

  • F06

    Fault

    The boiler has detected a problem with the outdoor temperature sensor.

  • F07

    Fault

    The electrical supply voltage is too low for normal operation.

  • F09

    Control fault

    The control board may be faulty or unconfigured. The user guide also lists a short circuit on the gas valve as a possibility.

  • F10

    Fault

    The boiler detected a fault generating the ignition spark.

  • F12

    Fault

    The moving part of the circulation pump is jammed.

  • F13

    Fault

    The boiler reports a fault in the circulation pump or its electrical circuit.

  • F14

    Fault

    The electrical supply voltage is too high for normal operation.

  • F15

    Fault

    The boiler reports a fault in the circulation pump or its electrical circuit.

  • F16

    Fault

    The boiler detected a fault in the gas valve or its circuit.

  • F17

    Fault

    The boiler reports a fault in the circulation pump or its electrical circuit.

  • L0C

    Lockout

    The boiler recorded five restarts within 15 minutes.

  • L0d

    Lockout

    The boiler locked out during ignition. A restriction in the flue or condensate drain may be involved.

  • L04

    Sensor fault

    The sensor measuring water temperature as it leaves the boiler is giving a faulty reading.

  • L05

    Sensor fault

    The sensor measuring water temperature as it returns to the boiler is giving a faulty reading.

  • L06

    Lockout

    The controls detected a flame signal before opening the gas valve.

  • L09

    Control fault

    The control board may be faulty or unconfigured. The user guide also lists a short circuit on the gas valve as a possibility.

Source Ideal Heating manufacturer documentation.