Ideal Heating boiler fault codes
Codes and operating messages for Logic Combi² C24, C30 and C35. Check your exact boiler model before using this guide.
27 results
- F01
Fault
The heating circuit pressure is below the level the boiler needs to operate correctly.
- L02
Lockout
The burner could not light and the boiler has locked out. A gas supply fault or blocked condensate drain can be involved.
- L01
Lockout
The boiler has locked out after a high flow temperature reading. A lack of water circulation can cause this.
- dU
Service mode
The diverter valve is held between the heating and hot-water positions for servicing.
- F0C
Fault
There is a fault with the hot-water temperature sensor.
- F0t
Fault
There is a problem with the room thermostat or its connection to the boiler.
- F0U
Fault
The outgoing water is over 50°C hotter than the returning water. Poor circulation can cause this.
- F02
Fault
The boiler lost its flame during operation.
- F03
Fault
The boiler detected a fault in the fan or its electrical circuit.
- F04
Sensor fault
The sensor measuring water temperature as it leaves the boiler is giving a faulty reading.
- F05
Sensor fault
The sensor measuring water temperature as it returns to the boiler is giving a faulty reading.
- F06
Fault
The boiler has detected a problem with the outdoor temperature sensor.
- F07
Fault
The electrical supply voltage is too low for normal operation.
- F09
Control fault
The control board may be faulty or unconfigured. The user guide also lists a short circuit on the gas valve as a possibility.
- F10
Fault
The boiler detected a fault generating the ignition spark.
- F12
Fault
The moving part of the circulation pump is jammed.
- F13
Fault
The boiler reports a fault in the circulation pump or its electrical circuit.
- F14
Fault
The electrical supply voltage is too high for normal operation.
- F15
Fault
The boiler reports a fault in the circulation pump or its electrical circuit.
- F16
Fault
The boiler detected a fault in the gas valve or its circuit.
- F17
Fault
The boiler reports a fault in the circulation pump or its electrical circuit.
- L0C
Lockout
The boiler recorded five restarts within 15 minutes.
- L0d
Lockout
The boiler locked out during ignition. A restriction in the flue or condensate drain may be involved.
- L04
Sensor fault
The sensor measuring water temperature as it leaves the boiler is giving a faulty reading.
- L05
Sensor fault
The sensor measuring water temperature as it returns to the boiler is giving a faulty reading.
- L06
Lockout
The controls detected a flame signal before opening the gas valve.
- L09
Control fault
The control board may be faulty or unconfigured. The user guide also lists a short circuit on the gas valve as a possibility.