Vaillant boiler fault codes
Codes and operating messages for ecoTEC plus 826, 832, 836 and 840 (CS/1-5). Check your exact boiler model before using this guide.
115 results
- F.022
Fault
The boiler has too little water or the heating circuit pressure is below the operating range.
- F.028
Fault
The boiler could not confirm a flame when it tried to light. After five failed attempts, it goes into fault mode.
- F.075
Fault
Heating water pressure rose too little when the pump started. The pump, pressure sensor or water circuit may be involved.
- F.000
Fault
The boiler lost the signal from the flow water temperature sensor.
- F.001
Fault
The boiler lost the signal from the return water temperature sensor.
- F.002
Fault
The signal from the hot-water outlet temperature sensor has dropped out.
- F.003
Fault
The controls have lost the cylinder temperature signal, where a cylinder is fitted.
- F.010
Fault
The flow temperature sensor circuit has shorted.
- F.011
Fault
The return temperature sensor circuit has shorted.
- F.012
Fault
The hot-water outlet temperature sensor circuit has shorted.
- F.013
Fault
The cylinder temperature sensor circuit has shorted, where fitted.
- F.020
Fault
The flow or return water exceeded its temperature limit. The safety cut-out stopped gas to the burner.
- F.023
Fault
The temperature difference between the flow and return pipes is too large.
- F.024
Fault
The boiler water is getting hot too quickly, which can indicate a circulation problem.
- F.025
Fault
The flue gases are above their permitted temperature.
- F.027
Fault
A flame signal was picked up while the burner was off.
- F.029
Fault
The flame went out during operation and the boiler could not relight it.
- F.032
Fault
The fan is running outside the expected speed range.
- F.035
Fault
The boiler detected a restriction in the air or flue pipe.
- F.040
Fault
The burner is getting less air than expected for the amount of gas supplied.
- F.042
Fault
The boiler detected an invalid appliance or gas group coding resistor.
- F.044
Fault
The flame-sensing signal is too weak and automatic compensation could not correct it.
- F.047
Fault
The internal cylinder’s hot-water outlet sensor gave an implausible reading, where fitted.
- F.049
Fault
The eBUS control connection has shorted, or two active eBUS units have reversed polarity.
- F.057
Fault
Combustion control failed and the boiler could not continue in its backup mode.
- F.061
Fault
An internal control chip did not respond within its expected timing.
- F.062
Fault
The flame signal was still present longer than expected after the burner stopped.
- F.063
Fault
The controller detected a read or write error in its internal memory.
- F.064
Fault
The electronics could not interpret the signal from a sensor.
- F.065
Fault
An electronic component is running above its temperature limit.
- F.067
Fault
The system that checks for a flame reports a fault.
- F.068
Fault
The flame sensor is reporting an unstable signal.
- F.070
Fault
The device identification number is missing, incorrect or incompatible with the coding resistor.
- F.071
Fault
The flow water temperature sensor gave a reading outside the expected values.
- F.072
Fault
The flow and return temperature readings differ outside the expected range.
- F.074
Fault
The boiler has lost the water pressure sensor signal.
- F.076
Fault
The main heat exchanger’s overheat protection has operated.
- F.077
Fault
The condensate pump or a flue non-return flap is preventing the burner from running, where fitted.
- F.078
Fault
The boiler is connected to a controller it does not support.
- F.080
Fault
The cold-water inlet sensor for the internal cylinder is faulty, where fitted.
- F.081
Fault
The boiler could not heat the hot-water cylinder as requested.
- F.083
Fault
The temperature sensors detected little or no warming after the burner started.
- F.084
Fault
The difference between the flow and return temperature readings does not make sense to the controls.
- F.085
Fault
The boiler has detected temperature sensors in the wrong positions.
- F.087
Fault
The spark transformer is disconnected from the control board.
- F.088
Fault
The electrical connection to the gas valve has been interrupted.
- F.089
Fault
The installed pump does not match the boiler model.
- F.090
Fault
The boiler has lost communication with the internal cylinder controls, where fitted.
- F.092
Fault
The procedure to change the gas type was not completed correctly.
- F.095
Fault
The gas valve motor has reached the lowest allowed position.
- F.096
Fault
The gas valve motor has reached the highest allowed position.
- F.097
Fault
The main control board failed its self-test.
- F.105
Fault
The controller needs the correct adjustment value for the gas valve, for example after a component is replaced.
- F.110
Fault
The boiler could not confirm ignition when using a richer gas and air mixture.
- F.194
Fault
The power supply to the control board has a fault.
- F.195
Fault
The boiler detected a significant drop in its supply voltage.
- F.196
Fault
The boiler detected a significant rise in its supply voltage.
- F.228
Fault
The burner failed to light at start-up while the boiler was running in backup mode.
- F.229
Fault
The flame went out in backup mode and the burner could not light again.
- F.235
Fault
The first start-up detected a blockage in the air-inlet or flue path.
- F.281
Fault
The flame went out shortly after lighting, while it was stabilising. After five failed attempts the boiler goes into fault mode.
- F.291
Fault
After a flame loss during operation, the flame could not stabilise during the next start.
- F.317
Fault
The hot-water flow sensor is reporting an implausible reading.
- F.318
Fault
The motorised valve that switches between heating and hot water is not moving.
- F.320
Fault
The circulation pump is jammed and its automatic release attempt failed.
- F.321
Fault
The pump’s built-in electronics have a fault.
- F.322
Fault
The circulation pump overheated and the backup mode could not cool it down.
- F.323
Fault
The pump is running without water in it.
- F.324
Fault
The wiring connection to the circulation pump has been interrupted.
- F.325
Fault
The circulation pump is reporting a fault.
- F.326
Fault
A test found two or more water circuit components that did not respond as expected.
- F.327
Fault
The minimum heating flow is limited because no domestic hot-water circuit is connected.
- F.330
Fault
The pump did not respond to commands during the water circuit test.
- F.334
Fault
The flue configuration setup was left unfinished.
- F.336
Fault
The boiler has detected a configuration it does not permit.
- F.337
Fault
The shared-flue kit is incompatible with the model’s heating unit.
- F.338
Fault
The controls have detected incorrect settings for a shared flue.
- F.342
Fault
Airflow to the burner is outside the permitted range.
- F.343
Fault
The combustion air mass-flow sensor is sending an implausible reading.
- F.344
Fault
The flame-sensing electrode can no longer operate within its limits.
- F.347
Fault
Condensate was detected in the combustion chamber, so the burner stopped.
- F.363
Fault
The display’s memory failed its read and write test.
- F.707
Fault
The display and the main control board are not communicating.
- F.905
Fault
The boiler’s communication interface is switched off.
- L.016
Temporary backup mode
The boiler detected flame loss while operating at its lowest output.
- L.022
Temporary backup mode
Too little water is circulating through the heating circuit.
- L.025
Temporary backup mode
The cold-water inlet temperature sensor circuit has shorted.
- L.032
Temporary backup mode
The water flow sensor is faulty or sending an implausible reading.
- L.095
Temporary backup mode
The gas valve motor has reached the lowest allowed position.
- L.096
Temporary backup mode
The gas valve motor has reached the highest allowed position.
- L.097
Temporary backup mode
The boiler measured too little air in the gas and air mixture.
- L.105
Temporary backup mode
The boiler could not complete its automatic air purge.
- L.144
Temporary backup mode
The flame-sensing signal is too weak and automatic compensation failed.
- L.194
Temporary backup mode
The power supply to the control board has a fault.
- L.195
Temporary backup mode
The controls detected a drop in the power supply voltage.
- L.196
Temporary backup mode
The controls detected a rise in the power supply voltage.
- L.319
Temporary backup mode
The internal bypass valve is jammed.
- L.320
Temporary backup mode
The pump is jammed. The boiler is trying to release it automatically.
- L.322
Temporary backup mode
The pump electronics have overheated.
- L.343
Temporary backup mode
The combustion air mass-flow sensor is sending an implausible reading.
- N.013
Backup mode
The water pressure sensor reading is implausible.
- N.027
Backup mode
The hot-water outlet temperature sensor gave an implausible reading.
- N.032
Backup mode
The water flow sensor is faulty or sending an implausible reading.
- N.089
Backup mode
The installed pump does not match the boiler model.
- N.095
Backup mode
The gas valve motor has reached the lowest allowed position.
- N.096
Backup mode
The gas valve motor has reached the highest allowed position.
- N.097
Backup mode
The boiler measured too little air in the gas and air mixture.
- N.100
Backup mode
The boiler lost communication with the outdoor temperature sensor.
- N.144
Backup mode
The flame-sensing signal remains weak after another automatic compensation attempt.
- N.194
Backup mode
The power supply to the control board has a fault.
- N.270
Backup mode
The temperature difference across the secondary heat exchanger is too large, so the boiler switched to backup control.
- N.317
Backup mode
The hot-water flow sensor is reporting an implausible reading.
- N.319
Backup mode
The internal bypass valve is jammed.
- N.324
Backup mode
The wiring connection to the circulation pump has been interrupted.
- N.343
Backup mode
The combustion air mass-flow sensor is sending an implausible reading.